Which of the following is a TYPICAL defect found in functional completeness testing?
Which pair of statements correctly describes when functional completeness, functional correctness and/or functional appropriateness are undertaken?
Your company is developing a new website that will be accessed by many user roles, including adults, seniors and children. You must test to ensure that the website is appropriate for all these roles, i.e. it meets their needs and would be considered acceptable by them.When would be the BEST time for this testing to commence?
A new online application is being introduced for the start of the next tax year to handle tax liabilities. This web based system is especially aimed at those with visual disabilities and several innovative features are being introduced for the user interface. The design of these features is ongoing.Which of the following represents the BEST approach for accessibility testing?
You are testing a hospital patient management system. New or amended patient data is captured by hospital administrators using an in-house patient capture application and transmitted to one or more hospital departments depending on the nature of the medical condition. Each department operates its own software package. There has been a change to the patient capture application and you are going to run a series of interoperability tests.Which TWO of the following are potential interoperability defects?The patient name field is truncated on one of the receiving department systems.Hospital administrators find the new patient-capture application screens difficult to navigate.Two department systems are unable to recognise the format of international telephone numbers for foreign patients.Existing patient data takes too long to retrieve by the patient-capture application.There are spelling errors in the field names on some screens.
You work for a company who are pioneers in smart energy technology. One of their core products is their energy monitor in-home display device, used to display current and historic energy consumption data to many thousands of customers. It has been designed to integrate with their other smart home products, including domestic lighting control systems via their HomeHub.The energy monitor in-home display device has been designed to interact with the home’s lighting system and automatically dim bedroom lights when the daily energy budget has reached 90%. A defect has been found in the energy monitor's software which causes lights to be dimmed at 80% of the daily budget. What type of testing would MOST likely have uncovered this defect?