For several days, an administrator notices the following alerts:✑ CVM NIC Speed Low Warning Alerts✑ Warning Alerts of CVM NIC not performing at optimal speed✑ CVM is disconnected from the network Critical Alert✑ Network Visualization page shows excessive dropped packets on CVM/Host.Which steps should be taken to determine which problem should be addressed first?A.✑ Access the Hardware Page to verify resources are available✑ Analyze all CVM Speed Alerts in the Alerts/Events page✑ Analyze output for the network and interface properties and connectivity issuesB.✑ Verify Host/CVM connectivity on the Network Visualization page✑ Use to verify the bridge and bond configuration✑ Review alerts/events page for the CVM disconnected errorC.✑ Review Alerts page for NIC speed alerts and alert timing✑ Analyze the genesis.out log file for process failures✑ Assess the NIC properties in the Network Visualization > Host Properties pageD.✑ Restart networking services on the CVM✑ Determine the current configuration of the affected CVM via output✑ Access the Alerts/Events page for the CVM network connection failures
An administrator needs to relocate an AHV cluster to a new datacenter during a maintenance window. The cluster will use the same IPs in the new datacenter.Which two steps should be taken to prepare for this task? (Choose two.)
An administrator needs to evaluate if the existing configuration of Protection Domains meets the specified corporate recovery policy for SQL Data. The corporate policy requires that all SQL Servers be recoverable at the DR site within 30 minutes, and must result in a maximum of 60 minutes of data loss. SQL data must be required.The protection domain is configured as follows:✑ Application consistent snapshots are enabled✑ The SQL server VMs are assigned to the Protection Domain as their own Consistency Group✑ The Protection Domain schedule is configured as snapshots taken every 90 minutes from 7 am until 8 pmWhat must be changed to meet the required policy?
An administrator needs to make sure an RF3 cluster can survive a failure of two complete racks without negatively affecting performance. The current cluster configuration consists of the following:✑ 30 All Flash Nodes: distributed 10 nodes per rack across three 42U racks✑ Each node is configured with 20TB usable storage all flash (Cluster Total 600TB Usable)✑ Current cluster utilization is 500TB storage✑ Storage containers have Erasure Coding enabledWhich configuration changes should be made to make sure the cluster meets the requirements?
An administrator receives an error indicating that the CVMs in the cluster are not syncing to any NTP servers. An investigation of the issue finds:✑ The NTP servers are configured in Prism✑ The time on all CVMs is the same✑ Both the CVMs and AHV hosts are configured for the UTC time zoneWhich two steps can be taken to troubleshoot this issue? (Choose two.)
HOTSPOT -An administrator is configuring an All Flash cluster to support the following workloads:✑ Full clone virtual desktops✑ Hadoop✑ Write heavy databasesWhich correct configuration options should the administrator use to meet the item requirements? For each procedure, indicate whether it is a correct or incorrect procedure that must be configured to meet the item requirements using the drop-down option.Hot Area: