Ready to Pass Your Certification Test

Ready to guarantee a pass on the certification that will elevate your career? Visit this page to explore our catalog and get the questions and answers you need to ace the test.

vmware 5V0_2121

Custom view settings

Exam contains 100 questions

Page 3 of 17
Question 13 🔥

An architect is designing for a production vSAN cluster, and the customer introduced these requirements related to File Services:✑ A minimum of 12 files shares.✑ 30TB NFS capacity to mount workload VMs.What should be the architect's recommendations?

Which database solution meets these requirements?
Highly voted
Highly voted
Highly voted
Highly voted
Discussion of the question
Question 14 🔥

An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.The following information is known about the vSAN Cluster:✑ vSAN 7.x Cluster✑ vSAN node count: 8✑ De-Duplication and Compression: Enabled.✑ Encryption: DisabledCurrent Utilization: 45%✑ Disk Groups: 2✑ Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSDWhich three steps should the administrator take to successfully complete the task? (Choose three.)

Which database solution meets these requirements?
Highly voted
Highly voted
Highly voted
Highly voted
Highly voted
Highly voted
Discussion of the question
Question 15 🔥

A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.What will be the status of the vSAN objects on the affected host immediately after it is recovered?

Which database solution meets these requirements?
Highly voted
Highly voted
Highly voted
Highly voted
Discussion of the question
Question 16 🔥

Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.The current vSAN cluster has the following configuration:✑ 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM✑ 1 Disk Group per vSAN node- 1 x 400 GB- 4 x 1.8 TB✑ De-duplication and Compression is enabled.✑ vSAN Capacity is currently:- Total: 72 TB- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

Which database solution meets these requirements?
Highly voted
Highly voted
Highly voted
Highly voted
Highly voted
Discussion of the question
Question 17 🔥

After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1(vSAN Traffic).Which step should be taken to resolve this issue?

Which database solution meets these requirements?
Highly voted
Highly voted
Highly voted
Highly voted
Discussion of the question
Question 18 🔥

In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

Which database solution meets these requirements?
Highly voted
Highly voted
Highly voted
Highly voted
Discussion of the question

Lorem ipsum dolor sit amet consectetur. Eget sed turpis aenean sit aenean. Integer at nam ullamcorper a.

© 2024 Exam Prepare, Inc. All Rights Reserved.